CYS Series(One Motor) 2019-03-04T05:22:19+00:00

Project Description

CYS Series

Six Models
CYS-C1
Max pressure:8.0Bar;         Max power:380V   7.5KW
CYS-C2
Max pressure:8.0Bar;        Max power:380V   15.0KW
CYS-C3
Max pressure:8.0Bar;        Max power:230V    7.5KW
CYS-C4
Max pressure:15.0Bar;      Max power:380V    7.5KW
CYS-C5
Max pressure:15.0Bar;      Max power:380V    15.0KW
CYS-C6
Max pressure:15.0Bar;      Max power:230V    7.5KW
1.FUNCTION INTRODUCTION
1.1 Automatic detection of three-phase line order to prevent equipment from reverse.
1.2 Automatic detection of missing phase.
1.3 Real-time monitoring of pressure, current and voltage.
1.4 Real-time monitoring of over-voltage, under-voltage and over-current. Abnormal immediately alarm, display specific alarm reasons.
1.5 Pressure range can be set as required.
1.6 Two pressure units(Bar/Psi) can be free to switch.
1.7 Display equipment running time.
1.8 Automatic exhaust valve.
1.9 Cumulative work more than 8 hours, equipment automatic drainage.
1.10 Automatic reminder of low oil level.
2. INSTALLATION GUIDE

WIRING DIAGRAM OF CONTROLLER

2.1 Install the sensor:The Lead end of sensor must be installed face up.
2.2 Wiring: Open both sides of the yellow cover area, wiring in strict accordance with the wiring diagram. (24V NC type exhaust solenoid valve should be selected.)
2.3 First start: All valves must be closed. Open the equipment to achieve the maximum pressure, then can be used for normal use.(If there is the alarm phenomenon of over-current, locked-rotor and so on for the first time to start the equipment, reset to the factory settings before the operation above.)
3. OPERATION PANEL & BUTTONS
3.1 OPERATION PANEL INTRODUCTION

OPERATING PANEL

1 Power key
2 “↑”key
3 “↓”key
4 Pressure unit
5 Current air pressure
6 Running state
7 Running time
8 The current
9 Cause of failure
3.2 BUTTONS INTRODUCTION
3.2.1 Setup interface: Long press the “start/stop” button and “↓” key 6s at the same time to show setup interface. Click the “start/stop” button to switch settings.
3.2.2 Save settings: a) Long press the “start/stop” button and “↓” key 6s at the same time to save the parameters. b) After setting the parameters, wait for 20s, it will automatically exit from the setup interface and save the parameters.
3.2.3 Remove alarm: Click “start/stop” button to remove the alarm.
3.2.4 Switch pressure unit: Click the “↓” key to switch pressure unit ( Bar /Psi).
3.2.5 Factory setting: Long press the three buttons 6s at the same time to restore the factory default settings.
3.2.6 View the reference current: Long press “↑” to view the reference current.
APPENDIX: POWER &AIR PRESSURE SETTING INTERFACE ILLUSTRATION, INDEX VALUE & SETTING PARAMETERS RELATIONAL TABLES

POWER SETTING INTERFACE

【1.Index value  2.Power setting value 】

AIR PRESSURE SETTING INTERFACE

【1.Index value  2.Pressure setting value  】

Index value Setting parameters
0
Power(KW)setting:0(Default)
/1.00/1.10/1.20/…/7.40/7.50/…/14.90/15.00
1 Set maximum pressure:8Bar(Default)
2 Set minimum pressure:6Bar(Default)
3 Pressure unit:1(Default)stands for Bar,2 stands for Psi

index value and setting parameters

4.ALARM PHENOMENON
4.1 Line order alarm:
“LO” lights up when line order error is happened. It can not be turned on and interface turns red when the alarm occurs. Buzzer blaring.
4.2 Missing phase alarm:
“DP” lights up when missing phase is happened. It can not be turned on and interface turns red when the alarm occurs. Buzzer blaring.
4.3 Over current alarm:
After being turned on, if the current abnormally increases, “OC” lights up. Shut down and interface turns red when the alarm occurs. Buzzer blaring.
4.4 Oil level alarm:
when the oil pressure over lowering in power-on state, “OL” lights up, Shut down and interface turns red when the alarm occurs. Buzzer blaring.
4.5 Other alarm:
When being turned on for first time, if no increase in pressure or current abnomality, shut down and alarm. Screen flickers three times and buzzer short sounds three times.
5. SECURITY MATTERS
5.1 Reminder:
Be sure to note the following safety rules in all processes using this controller. The company shall not be responsible for any personal injury or property loss as a result of violation of the provisions.
5.2 Do not operate in an explosive environment.
Do not use the instrument in place where there are flammable and explosive materials. In this environment, the use of any electrical equipment are likely to cause harm to safety.
5.3 Wiring in strict accordance with the drawings
Wiring in strict accordance with the drawings, It is forbidden to connect multiple air-end to the same terminal.
5.4 Earth wire
Ensure that the earth wire is connected before turn on the power to prevent electric shock.
5.5 Power supply
Energize the controller and ensure that the supply voltage matches the rated voltage.
5.6 Please do not remove any shell part without authorization
It works with high voltage in some parts of the controller, do not take off the controller shell or any part of the controller mainboard without special permission.