CYE Series(One Motor) 2019-03-21T07:37:33+00:00

Project Description

CYE Series(One Motor)
 Two Models
CYE-A1
Max pressure:8.0Bar;       Max power:220V    2.2KW;         110V    1.1KW;
CYE-A2
Max pressure:12.5Bar;     Max power:220V    2.2KW;         110V    1.1KW;
1. FUNCTION INTRODUCTION
1.1 Real-time display of pressure, current and voltage.
1.2 Real-time monitoring of over-voltage, under-voltage and over-current. Abnormal immediately alarm and display the corresponding error code.
1.3 Pressure range can be set as required.
1.4 Two standard operating voltage(220V/110V) can be free to switch.
1.5 Two pressure units(Bar/Psi) can be free to switch.
1.6 Display equipment running time.
2. INSTALLATION GUIDE
    WIRING DIAGRAM OF CONTROLLER
2.1 Install the controller on the air compressor vertically, and screw the joint of sensor to fix the controller.
2.2 Wiring: Wiring in strict accordance with the wiring diagram.
2.3 First start: All valves must be closed. Open the equipment to achieve the maximum pressure, then can be used for normal use. If there is the alarm phenomenon of over-current, locked-rotor and so on for the first time to start the equipment, reset to the factory settings before the operation above.
3. OPERATION PANEL & BUTTONS
3.1 OPERATION PANEL INTRODUCTION

OPERATING PANEL

1 Power key
2 “↑”key
3 “↓”key
4 Current air pressure
5 Running state
6 Pressure unit
3.2 BUTTONS INTRODUCTION
3.2.1 Setup interface: Long press the “start/stop” button and “↓” key 3s at the same time to show setup interface. Click the “start/stop” button to switch settings. (Tables 1)
3.2.2 Save settings: a) Long press the “start/stop” button and “↓” key 3s at the same time to save the parameters. b) After setting the parameters, wait for 10s, it will automatically exit from the setup interface and save the parameters.
3.2.3 Factory setting: Long press the three buttons 3s at the same time to restore the factory default settings.
3.2.4 View running time: In the shutdown state, long press the “start/stop” button 3s to display the cumulative running time
3.2.5 Switch pressure unit: Click the “↓” key to switch pressure unit ( Bar /Psi).
3.2.6 View the reference current: Long press “↑” 3s to view the reference current.
APPENDIX: AIR PRESSURE SETTING INTERFACE ILLUSTRATION, INDEX VALUE AND SETTING PARAMETERS RELATIONAL TABLES

AIR PRESSURE SETTING INTERFACE

【1.Index value  2 .Parameter setting value】

Index value Parameters setting
1 Set the maximum pressure: 8Bar(Default)
2 Set the minimum pressure: 6Bar(Default)
3 Power(W)setting:0(Default)、300、350、400、450、500、550……2000、2050、2100、2150、2200
4 Standard voltage(V):220(Default)、110
5 Display unit code:1(Default)stands for Bar,2 stands for Psi

INDEX VALUE AND SETTING PARAMETERS

4.ALARM PHENOMENON
4.1 Phenomenon one:

The front of the display pressure value flashing “A”,

indicating that the motor is in “over-current” or “locked” state, click the “S” button to check the current value of the over-current. Reboot after troubleshooting;

4.2 Phenomenon two:

The front of the display pressure value flashing “U”,

indicating abnormal voltage, is in “overpressure” or “undervoltage” state, click “S” button twice to check the abnormal voltage value. Reboot after troubleshooting;

4.3 Phenomenon three:

The front of the display pressure value flashing “P”,

indicating that the air compressor needs drainage. The mark will disappear automatically after draining;

4.4 Phenomenon four:

The front of the display pressure value flashing “H”.

indicating that abnormal gas pressure in tank, slow growth or no pressure to detect. Reboot after shutdown and troubleshooting; (This phenomenon only occurs when the controller is used for the first time);

 

5.1 Reminder
Be sure to note the following safety rules in all processes using this controller. The company shall not be responsible for any personal injury or property loss as a result of violation of the provisions.
5.2 Do not operate in an explosive environment
Do not use the instrument in place where there are flammable and explosive materials. In this environment, the use of any electrical equipment are likely to cause harm to safety.
5.3 Wiring in strict accordance with the drawings
Wiring in strict accordance with the drawings. It is forbidden to connect multiple air-end to the same terminal.
5.4 Earth wire
Ensure that the earth wire is connected before turn on the power to prevent electric shock.
5.5 Power supply
Energize the controller and ensure that the supply voltage matches the rated voltage.
5.6 Please do not remove any shell part without authorization
It works with high voltage in some parts of the controller, do not take off the controller shell or any part of the controller mainboard without special permission.

5.SECURITY MATTERS